Flat Single Pair Silica Insulated

 

Application :

  • These cables are used with thermocouples for temperature measurements.

Specification :

  • Conductor Solid. Material is according to thermocouple type.
    Insulation Silica
    Outer sheath Silica
    Construction Flat
    Color code According to IEC 60584-3
  •  

      NX silica insulated

K Type :

  • AWG(mm) Insulation Material Sheath Material Max. Temp. (°C) Nominal O.D. (mm) Weight (kg/km)
    24 (0.51) silica silica 870 2.2 x 3.4 16.7
    20 (0.81) silica silica 980 2.7 x 3.9 20.0
    14 (1.63) silica silica 1090 3.6 x 5.0 53.4

J Type :

  • AWG(mm) Insulation Material Sheath Material Max. Temp. (°C) Nominal O.D. (mm) Weight (kg/km)
    24 (0.51) silica silica 370 2.2 x 3.4 16.7
    20 (0.81) silica silica 480 2.7 x 3.9 20.0
    14 (1.63) silica silica 590 3.6 x 5.0 53.4

N Type :

  • AWG(mm) Insulation Material Sheath Material Max. Temp. (°C) Nominal O.D. (mm) Weight (kg/km)
    24 (0.51) silica silica 980 2.2 x 3.4 10.0
    20 (0.81) silica silica 980 2.7 x 3.9 11.7
    14 (1.63) silica silica 1090 3.6 x 5.0 26.7